Brand: Atwood
Looking for a owneroperator manual for a Atwood Mobile. I have 8525 iv furnace which want light blower com. Will not ignite, or fan blow. Thermostat seems OK. Need to replace the fan. Furnace does not ignite. Troubleshooting Atwood Hydro Flame Furnace: A Guide For Novice RVers. Tools And Gears You Need To Have Generally speaking, there is no need for you to gather high-level stuff in order to tackle “ Atwood hydro flame furnace won’t light ” issue. That being said, it’s quite difficult to troubleshoot the furnace of recreational vehicles.
Category: Thermostat
Type: Installation and operation manual for Atwood HYDRO FLAME 2H2C
Pages: 1 (0.11 Mb)
ENGLISH, FRANCAIS(et Canada)•Installation •Operation
LITERATURENUMBER
hydro flame
Model 2H2C
Digital Thermostat
9
12VDC
3
2
USED
4
COM
5
COM-
6
HI
7
LOW
Atwood Hydro Flame Furnace Thermostat Manual
8
FURNACE
(OFF) OFF
M
System Switch
Set
Set
Operating Voltage ......................9VDC to 18VDC
................................100mA
..................-40F to +185F
..............+55F to +90F
..+35F to +99F
................................+/- 1F
SCROLL ORDER OF
OPERATION
Scroll Order of Displayed Modes
•
AUFurnace automatically switches between high and low BTU valve and high
and low speed fan when cycling to satisfy set point.
HIFurnace high BTU valve and high speed furnace fan cycle to satisfy set point.
LOFurnace low BTU valve and low speed furnace fan cycle to satisfy set point.
HFFurnace fan runs at high speed to circulate air. Air conditioner fan does not run.
LFFurnace fan runs at low speed to circulate air. Air conditioner fan does not run.
Scroll Order of Displayed Modes
•
Air conditioner automatically switches compressor and high and low speed fan when
•
HIAir conditioner compressor and high speed fan operate to satisfy set point.
LOAir conditioner compressor and low speed fan operate to satisfy set point.
HFAir conditioner fan runs at high speed to circulate air. Furnace fan does not run.
Atwood Hydro Flame Thermostat 38453 Manual
LFAir conditioner fan runs at low speed to circulate air. Furnace fan does not run.
Scroll Order of Displayed Modes
•
HIAir conditioner fan and furnace fan run at high speed to circulate air.
LOAir conditioner fan and furnace fan run at low speed to circulate air.
Scroll Order of Displayed Modes
•
THERMOSTATINSTALLATION
Thermostat is very sensitive. HANDLEWITHCAREATALLTIMES.
Locate thermostat 48˝ to 54˝ above floor on an INTERIORwall.
Pick a dry area where air circulation is good. EXTERIORwall
location must have a 3/4˝ spacer between thermostat and
1. Be sure all electrical power has been disconnected from
the air conditioner, furnace and the power supply.
2. Do not install the thermostat where there are unusual
heating conditions: such as direct sunlight, heat produc-
ing appliances (television, radio, wall lamp, etc.)
3.
ATTACHINGTHEWALLTHERMOSTAT.Separate the thermostat
body from the sub-base by gently squeezing the top and
bottom. Pull wires through access hole in base plate.
Attach thermostat sub-base to the wall at the desired
mounting location. Mount the sub-base to the wall before
THISTHERMOSTATHASBEENDESIGNEDTOOPERATESTANDARDAIRCONDITIONINGUNITSINCONJUNCTIONWITHANEXCALIBUR2-STAGEFURNACE.
Atwood Hydro Flame Thermostat Manual
Note: Move jumper to
Atwood Hydro Flame Furnace Thermostat Manual
Unit. Discard jumper for
®
Related Products for Atwood HYDRO FLAME 2H2C
Related Manuals for Atwood HYDRO FLAME 2H2C
Atwood Hydro Flame Thermostat Manual
Atwood HYDRO FLAME 2H2C: Frequently viewed Manuals